VSI-Pro VIDEO SERIAL INTERFACE
The VSI-Pro provides two open collector transistor alarm outputs to trigger alarming devices. These are Alarm 1 & 2 in the
Alarm menu. Upon an Exception, a VSI-Pro can be programmed to trigger a VCR to go to its fastest record time, have
a Quad go full screen, home a switcher, trigger a preprogrammed PTZ, or provide visual or audible alarms. The VSI-Pro
provides two alarm outputs that are rated at 12VDC @ 20mA maximum.
The following are some basic circuit designs to take advantage of the alarm output option of the VSI-Pro.
5 VDC
Internal
To
VSI-Pro
Alarm 1 or 2
Output
LED
470 OHM
12 VDC
Internal
To
VSI-Pro
Alarm 1 or 2
Output
LED
1K OHM
5 VDC
Internal
To
VSI-Pro
Alarm 1 or 2
Output
RELAY SPDT 1N4001
5 VDC
Internal
To
VSI-Pro
Alarm 1 or 2
Output
BUZZER
Figure 142: Hard Alarm Output
APPENDIX I HARD ALARM OUTPUT