ADPRO FastTrace-R by Xtralis Installation and User Manual
Doc 13972_03 69
4.3.7 Connected Equipment
The Connected Equipment menu provides a number of sub-menus to configure the settings
that the FastTrace-R will use when interacting with external equipment such as video cameras,
microphones/speakers, alarm inputs and control output devices as well as the local monitor and
alarm relay contacts.
Figure 68: Connected Equipment Menu
General Alarm Relay Settings
The FastTrace-R is equipped with a normally open Form C relay contact for use with external
monitoring equipment, for example, a fire or burglar alarm monitoring panel. The General Alarm
Relay settings can be used to notify external equipment that the FastTrace-R has changed its
operational state.
The General Alarm Relay settings specify when the relay activates. The two options available
are:
On Event (default) - The relay is active (closed) when there is a event on the FastTrace-R
which has not been accepted by a VideoCentral system. Once all alarms have been cleared
(downloaded) the relay will revert to its normal (de-energised) state.
On Connection to Site - The relay is active (closed) while there is a valid connection to a
VideoCentral system. The operation shall happen regardless of who originated the call (i.e.
whether a remote operator has called into the system.